Aircond Health Check · 冷气健康检查

Know exactly what's
wrong with your unit.

Not cooling properly? Strange noise? Water dripping? Instead of guessing, we do a full inspection — check every component that matters, find the problem, and explain it to you clearly with a written report.

冷气制冷效果变差?有异响?漏水?与其猜测,不如让我们进行全面检查 — 检测每个关键部件,找出问题,并以书面报告清楚解释给您听。

10
Check Points
30–120
Minutes per unit
RM140
Per unit
What We Check

Ten check points.
Every visit.

We don't guess and we don't patch. Every health check covers these ten areas — giving you a complete picture of your unit's condition before any repair work begins.

我们不猜测,也不临时修补。每次健康检查涵盖以下10个检查点,让您在进行任何维修前全面了解机器状况。

Refrigerant Gas Pressure

Manifold gauges connected to measure current refrigerant pressure — confirms if gas level is correct or low.

接上压力表检查冷媒压力,确认是否正常或不足。

Compressor Running Amps

Current clamp test on the compressor — confirms it is drawing the correct amperage and not under stress or failing.

用电流钳测试压缩机运行电流,确认是否在正常范围内运作,排除过载或故障风险。

Sensor Check

Room temperature sensor and coil sensor tested — faulty sensors cause incorrect temperature readings and poor cooling.

检测室温传感器及盘管传感器,传感器故障会导致温度读数不准及冷却效果差。

Coil Condition

Evaporator coil inspected for dirt buildup, corrosion, or ice forming — all of which reduce cooling efficiency.

检查蒸发器是否积尘、腐蚀或结冰,这些情况都会降低制冷效率。

Drainage & Water Leaking

Drain pan and drain hose inspected — blockages are the #1 cause of water dripping from indoor units.

检查接水盘及排水管,堵塞是室内机漏水的首要原因。

Electrical & Wiring

Electrical connections, capacitor condition, and wiring inspected for loose connections, corrosion, or signs of overheating.

检查电气接头、电容及线路,排除松动、腐蚀或过热迹象。

Filter Condition

Front filter inspected and cleaned — a clogged filter restricts airflow and forces the compressor to work harder.

检查及清洁滤网,堵塞的滤网会限制气流并加重压缩机负担。

Outdoor Unit Condition

Outdoor condenser coil, fan motor, and casing inspected — dirty condenser coils are a common hidden cause of poor cooling.

检查室外机冷凝器、风扇电机及外壳,冷凝器积尘是冷效差的常见隐患。

Noise & Vibration Check

Unit run tested while listening for abnormal noise or vibration — rattling, grinding, or hissing sounds all point to specific faults.

运行测试,聆听是否有异常噪音或震动,异响可指向特定故障。

Thermostat & Remote Function

Thermostat response and remote control function verified — incorrect temperature control is often a sensor or PCB issue.

验证温控器及遥控器功能,温控不准通常与传感器或PCB有关。

The Report

Find the problem.
Explain it clearly.

At the end of every health check, we explain what we found — in plain language, not technical jargon. You get a written report covering every check point so you can make an informed decision on what to repair, when, and why.

每次健康检查结束后,我们会用简单易懂的语言解释检查结果,而非技术术语。您将获得一份涵盖所有检查点的书面报告,让您能做出明智的维修决定。

What's in Your Report

Provided after every health check, every visit

Gas pressure reading (actual vs normal)
Compressor amps reading (actual vs rated)
Sensor status — pass or fault
Coil condition — clean, dirty, or corroded
Drainage — clear or blocked
Electrical — connections tight, capacitor condition
Outdoor unit — coil and fan condition
Overall assessment — unit health summary
Recommended action — what needs fixing and why
Estimated repair cost — if repairs are required
Why Book a Health Check

Don't repair what
you can't diagnose.

Many aircond repair jobs fail because the wrong part gets replaced. A health check identifies the actual fault first — saving you money on unnecessary repairs.

01

Know Before You Spend

A health check costs RM140. It tells you exactly what's wrong before you commit to any repair. Avoid paying for parts you don't need.

02

Compressor Amps — The Real Indicator

Gas pressure alone doesn't tell the full story. Compressor running amps reveals whether the compressor is healthy, struggling, or about to fail.

03

Sensors Cause More Problems Than You Think

A faulty room or coil sensor causes incorrect temperature control, short-cycling, and poor cooling — and is often misdiagnosed as a gas problem.

04

Written Report You Can Keep

Not just a verbal update — you get a written report you can refer to, share with your building manager, or use to compare repair quotes.

Pricing · 收费

One flat rate.
No hidden charges.

Health check price is fixed per unit — regardless of how long it takes. Quote confirmed before we start.

健康检查按台收费,无论所需时间长短,收费固定。上门前确认报价,完工后无隐藏收费。

Unit Type
Price (per unit)
Wall Split Unit
Standard wall-mounted aircond · 分体壁挂式冷气
RM 140
Ceiling Cassette Unit
4-way ceiling cassette · 天花卡式机
RM 140
Health check fee covers inspection, report, and explanation — labour only. Any repair work required after the check is quoted separately before we proceed. Travel surcharge may apply outside Petaling Jaya / Damansara area.
健康检查费用涵盖检查、报告及解释说明,仅收人工费。检查后如需维修,将另行报价并经您确认后才进行。八打灵再也/白沙罗以外地区可能收取额外交通费。
Common Questions

Before you
book us.

When should I book a health check?

Any time your unit is not performing as expected — not cooling well, making unusual noise, dripping water, or showing an error code. Also useful as a yearly check-up even if the unit seems fine, to catch problems early before they become expensive.

Is the RM140 refunded if I proceed with repairs?

No — the health check fee is separate from repair costs. However, knowing exactly what's wrong before committing to repairs typically saves more than the RM140 by avoiding unnecessary part replacements.

How long does it take?

Minimum 30 minutes per unit for a straightforward inspection. Up to 2 hours if the fault requires deeper diagnosis — for example, tracing an intermittent electrical fault or identifying the source of a refrigerant leak.

Do you fix problems on the same visit?

If the repair is simple and we have the parts — yes, we can fix it on the same visit with your approval. For larger repairs (compressor replacement, coil replacement, PCB), we'll quote and schedule a follow-up visit.

What brands do you check?

All major brands — Daikin, Panasonic, Mitsubishi, Samsung, LG, Midea, Acson, York, Carrier, Haier, Gree, and more. The health check process is brand-independent.

Book a health
check today.

Tell us your unit type, how many units, and your location. We'll confirm availability and get to the bottom of what's wrong.