Case Studies

Real Projects, Real Results

A closer look at how we design, install and commission air conditioning systems for offices, schools and commercial buildings across Petaling Jaya, Selangor and Kuala Lumpur.

Commercial Office · VRV

Multi-Floor VRV System for Munchy's Office

Selangor · Level 23 & 26
The Challenge

A two-floor corporate office needed consistent, quiet cooling across open-plan workspaces, meeting rooms and enclosed offices — with the flexibility to run floors independently.

What We Did

Designed and installed a full VRV system on Level 23 with 12 outdoor condensers and 32 ceiling cassettes, plus 18 wall-split units on Level 26. Works covered refrigerant piping, electrical, drainage, and an auto-changeover distribution board with run indicators and high-temperature alarm.

12 VRV Systems32 Ceiling Cassettes18 Wall SplitsAuto-Changeover DB
See project photos →
Commercial Office · Cassette + Split

32-Unit Office Fit-Out for LGMS Berhad

Selangor · Themed Office Interior
The Challenge

A design-led office with a bold themed interior needed cooling that performed evenly across open-plan areas, private offices, meeting rooms and a server room — without disrupting the aesthetic.

What We Did

Installed 32 indoor units — mostly ceiling cassettes across the open-plan floor, with 7 wall-mounted units in enclosed offices, meeting rooms and server areas. Layout and grille positions were planned around the interior design.

32 Indoor Units25 Ceiling Cassettes7 Wall Splits
See project photos →
Institutional · VRF

Institutional VRF for Sekolah Indonesia KL

Kuala Lumpur · Block B
The Challenge

An entire school block — classrooms, admin areas and common spaces — required reliable, easy-to-maintain cooling that could handle high daytime occupancy.

What We Did

Delivered a full VRF installation for Block B: 4 VRF outdoor systems serving 50 wall-mounted indoor units, using Panasonic FSV EX. Corridor M&E and cable-tray works were coordinated throughout the block.

4 VRF Systems50 Wall UnitsPanasonic FSV EX
See project photos →
Commercial Office · Daikin VRV · In Progress

Daikin VRV Install for Lam Soon Management Services

Selangor · Currently On Site
The Challenge

A commercial office fit-out requiring a Daikin VRV system plus dedicated cooling for the server room and meeting room — installed cleanly around existing fire-protection services.

What We're Doing

Installing 2 Daikin outdoor systems (RXQ8AYM + RXQ12AYM) serving 6 indoor units (5 cassettes + 1 concealed ducted), plus a separate 3-unit split scope — 2 wall units for the server room and 1 cassette for the meeting room. Currently at piping, bracketing and commissioning stage.

2 Daikin VRV Systems6 VRF Indoor Units3 Split UnitsNitrogen Pressure Tested
See project photos →

Planning a project? Let's talk.

Free site assessment for commercial and VRV/VRF projects across PJ, Selangor & KL.

WhatsApp Us →